SWIM 2000 - Tecnical data

SWIM Controller SWC:

measuringe range:         23 hours, 59 minuten, 59,9999 seconds

timereference:               TCXO 10.000MHz (temperaturecompensated quarzoscillator)

frequency deviation:      temperaturerange -25 to 50°C: +/- 2,5ppm (+/- 0,009s/h)
                                      with aging:     +/- 1 ppm pro Jahr
                                      at 25 degree celsius adjusted to  +/- 0.1 ppm
power supply:                internal: 12V gel cell battery
                                      external: 100-240 V   50/60Hz
                                      or 12-18 V  DC

interfaces:                      4 complete RS232 interfaces (noParity,8 data, 1 stop)
                                      1x PC (9600 kBaud)
                                      1x displayboard (2400 kBaud) galvanical separated
                                      1x protocollprinter (2400 kBaud)
                                      1x videointerface (9600 kBaud) galvanical separated
                                      3  RS485 interfaces
                                      2x timingbus startside and turnside
                                      1x displayboard

connextions:                   SWT line start
                                       SWT line turn
                                       printer 1
                                       printer 2
                                       PC
                                       TV-Online
                                       displayboard
                                       SWSU Swimm Start Unit
                                       start (banana plugs)
                                       displayboard (banana plugs)
                                       2x Speaker Aktive
                                       headset
                                       audio Line In
                                       audio Line out

regulators:                      microphone
                                       headset
                                       audio in
                                       total volume

pilot lamp:                      general error
                                       external supply
                                       power
                                       charge

control panel:
                                      talk: to talk via SPA
                                      line test: test of the start-wire
                                       start: manual start

SWIM-Terminal SWT:

measuringe range:        23 hours, 59 minuten, 59,9999 seconds
timereference:               The SWT´s are sycronisized with 1/10000 clock from the SWC
frequency deviation:      see SWC
connextions:                  5x2 banana plugs
                                      for
                                      touchpad, relay judging platform, manual button
                                      and
                                      RS485 input
                                      RS485 output


SWIM 2000 - gerneral information
sketch of the SWIM 2000 system
components of the SWIM 2000 system
pictures of the SWIM 2000 system

SWIM 2000 brochure
SWIM 2000 - timing - manual
SWIM 2000 - designer - manual